Elatec TWN4 - How to configure for Weigand 26 bit

Modified on Fri, 12 Nov 2021 at 02:51 PM

To make this configuration, you can use the AppBlaster->Configurable Project and the steps below.
 -Start AppBlaster (from DevPack406) -> Configurable Project
 -Choose the desired Template (eg. Multi Keyboard standard)
 -You have the option to add the needed Transponder (HID->HID Prox)
 -Under Transponder, you have an option to set Data Source/Bit Count, Bit Manipulation, and Output Format per your need
  In your case:
 -Data Source / Bit Count -> UID -> 26 Bits
 -Output Format -> Output Format -> Decimal
 -Output Format -> Output Bits -> (First Bit -> 9, Number of Bits -> 16)
 Under Version Information, we recommend that you rename the project according to your need.
  (To have information about the naming scheme of firmware images and version strings, you can refer to the TWN4DevPack406\Docs\TWN4 System Overview DocRev30.pdf, especially 2.6 Versioning Scheme and 2.7 App & Firmware Images.)

 Click on the "Save" button to save the project (.abp) file, which could be used for further modification.

 Click Create Image - to create a firmware image file into the path where you saved the .abp file.
 Program Image - to set created firmware image into the reader

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article