IDP Smart 51, 31 , 21 interpreting colour sensor values

Modified on Thu, 24 Aug, 2023 at 9:46 AM

If you are seeing ribbon calibration sync issues which manifest as large blocks or Yellow or Green in the print check the 'Red/Green/Blue on White Panel' after calibration


 1. If one of them is under 1,000, please replace the Color Out Sensor.


 2. If all of them are under 1000, please replace the Color In Sensor. (Sometimes the color out sensor is the cause when it doesn't turn on.)


You can check these values  with CardPrinterDiagnostic.exee included on the installation CD/Download.