Evolis Avanisa Auto Sensor Adjustment

Modified on Thu, 15 Dec, 2022 at 9:51 AM


To do the adjustment you will need to go into the service mode.


1. Remove both ribbon and film cartridge from the printer and close the front panel.


1. Hold down MENU and at the same time press UP, DOWN ,UP, DOWN  to enter the service mode.


2. Press DOWN key once to display Sensor Check, then press SET


3. Press DOWN Key 4 times to display AUTO ADJUSTMENT , press SET to initiate the Auto Adjsutment


4. Pres MENU twice to see Exit Menu SET, press SET to exit.


5. re-install the ribbon and film cartridge.



The printer sensors should now be calibrated.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article