Evolis Primacy CLM Calibration routine

Modified on Mon, 08 Jun 2020 at 11:43 AM

To calibrate the Card Lamination Module on a Evolis Primacy Use the Clam;1;Sa command to adjust all sensors at once:

 

a) Check that there is a lamination ribbon in the lamination module

b) Enter the Clam;1;Sa command

c) Open and close the cover.

d) The laminator will adjust the sensors in the following order:


1: Cover sensor

 2: Came head sensor

 3: Sync card sensor

4: Card exit sensor

5: Flip rot sensor

6: Flip card exit sensor

7: Rib rot pull sensor

8: Rib rot brake sensor

9: Black mark sensor

 

e) If the response is OK, the sensors have been adjusted A "timeout" message may appear if it takes too long to complete this procedure.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article