Evolis Primacy CLM Calibration routine

Modified on Mon, 8 Jun, 2020 at 11:43 AM

To calibrate the Card Lamination Module on a Evolis Primacy Use the Clam;1;Sa command to adjust all sensors at once:

 

a) Check that there is a lamination ribbon in the lamination module

b) Enter the Clam;1;Sa command

c) Open and close the cover.

d) The laminator will adjust the sensors in the following order:


1: Cover sensor

 2: Came head sensor

 3: Sync card sensor

4: Card exit sensor

5: Flip rot sensor

6: Flip card exit sensor

7: Rib rot pull sensor

8: Rib rot brake sensor

9: Black mark sensor

 

e) If the response is OK, the sensors have been adjusted A "timeout" message may appear if it takes too long to complete this procedure.