Adhesive cleaning cards are slightly longer than a CR80 card is, sometimes the printer doesn't identify the cleaning card.

First check card length detection is activated on the printer:
- Run "Rclc" command
> e/E answer means detection is enabled,
> d/D answer means it is deactivated. Please run "Pclc;e" to enable the feature.

Then, if problem remains the same, please proceed to the following:
0- Update to latest firmware version
1- Send the command Pem;2 (After you're done Pem;0 revert this setting)
2- Put a blank CR80 card in the feeder and run "Sie" command
3- Read the value measured with the command "Rclt;l"
(let say you obtained 1003 as an example)
4- Put an adhesive card in the feeder (no need to peel it off) and run "Sie" command
5- Read the value measured with the command Rclt;l
(let say obtained value is 1054 as an example)
6- Threshold value to determine which is CR80 card and which is adhesive card should be the middle value of the 2 previous values.
You can read current printer threshold value with "Rclt" command.
(let say obtained value is 1040)
7- If value obtained in 6 is not middle of 2 other values, then run "Pclt;<middle value>"
(as in my example, ideal value would be (1054+1003)/2=1028) I would have to run "Pclt;1028" as 1040 is above middle ideal value.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!